AMR WinControl & ALMEMO View - The Versions in Comparison
| Funktionen | ALMEMO View | AMR WinControl |
||||
| WC1 (Light) | WC2 (Standard) | WC3 (Profi) | WC4 (Server) | WCV (Monitoring) | ||
Measured values scanning |
||||||
| Number of measuring points supported | 4 | 20 | unlimited | unlimited | unlimited | unlimited |
| Number of connections supported | 1 | 1 | unlimited | unlimited | unlimited | unlimited |
| Support for ALMEMO® network | ||||||
| Fast scanning of measured values for V7 devices (up to 1000mops online) | ||||||
Connection types |
||||||
| Serial (COM-Port) | ||||||
| Network(TCP/IP, LAN, VPN, RAS) | ||||||
| Modem, GSM, and wireless modem support | ||||||
| Schedule-controlled connection setup | ||||||
Data Display
Data Display |
||||||
| Numeric display of measured values | ||||||
| Analogdisplay of measured values (wind rose, round gauges) | ||||||
| Overview | ||||||
| Data Table | ||||||
| Bar diagrams | ||||||
| Line diagrams (with zoom) | ||||||
| XY diagrams (with zoom) | ||||||
| Project drawings | ||||||
| Workspaces | ||||||
| Save / Load Diagram Templates (presentation characteristics as format type) | ||||||
Version in Comparison - Data Storage, Analysis & Processing
Data storage |
||||||
| Manual storage on hard disk | ||||||
| Automatic storage | ||||||
| Automatic generation of daily, weekly, monthly files | ||||||
| Automatic saving on an event-controlled basis | ||||||
| Automatic storage with automatic transmission of files via E-Mail | ||||||
| Automated printing of files as line diagram or table | ||||||
| Automatic storage with automatic backup of measurement files | ||||||
| Fail-safe (only devices with failsafe mode and internal memory) | ||||||
Data analysis |
||||||
| Two measuring cursors with statistics function | ||||||
| Displaying local maximum and minimum values in a line graph | ||||||
| Loading comparative characteristics in a line graph | ||||||
Calculation channels |
||||||
| Global calculation channels | ||||||
| Local calculation channels for files already saved | |
|||||
| Calculations based on external table values | |
|||||
| Formula-Editor with syntaxhihglighting | |
|||||
| Formula templates for many applications | |
|||||
|
|
||||||
| Linking /splitting of files | ||||||
| Grouping measured value files in a particular folder (wild card search) | ||||||
| Grouping measured value files over a particular period of time | ||||||
Datareduction |
||||||
| Averaging function (ONLINE and OFFLINE) | ||||||
| Smoothing (over time / over number of values, ONLINE and OFFLINE) | ||||||
Data Import & Export
Exporting Data |
||||||
| Clipboard | ||||||
| File formats (MS-Excel XLS / XLSX, TXT / CSV, FAMOS, QS-STAT, DIAdem, binary) | ||||||
| Dynamic data exchange (DDE, OLE) | ||||||
| Online data transmission to MS-Excel | ||||||
| Online-Export to OPC-DA-Server | ||||||
| Export into (SQL-) databases via ODBC | ||||||
Importing data |
||||||
| ASCII (list, columns, table formats) | ||||||
| ALMEMO® View files | ||||||
| Online-Import from OPC-DA Server | ||||||
Programming of Measuring Points and Devices
Programming of measuring channels |
||||||
| Programming the characteristics of measuring points and devices | ||||||
| Automated scaling of third-party sensors | ||||||
| Save/load programming of the measuring points to/from file | ||||||
| Editing the programmed file (similar to Excel table) | ||||||
| Bulk-programming of selected channel properties | ||||||
Datalogger Functions |
||||||
| Programming of the data logger (incl. averaging functions) | |
|||||
| Read-out of data memory (all measured values) | |
|||||
| Read-out of data memory (selective) | |
|||||
| Display of memory occupancy status | |
|||||
Alarm Functions and Controllers
Alarm Functions |
||||||
| Alarm value display in measuring points list and in all measured value displays | ||||||
| Alarm report with confirmation and comments text | ||||||
| Eventlist (audit trail) | ||||||
| Start a program in the event of a particular fault | ||||||
| Send e-mail / SMS in the event of an alarml | ||||||
| Switch ALMEMO® output relays (specific to measuring point) | ||||||
| In case of an alarm, tones and sound recording are played back (via a sound card) | ||||||
| Control commands dependent on measured values (KwikScript) | ||||||
| Pre-Alarm | ||||||
| Printing Alarm-protocols | ||||||
| Schedules for alarm processing | ||||||
| Automatic checking of system configuration | ||||||
Controllers |
||||||
| Two-point controller with ALMEMO® output relays | |
|||||
| Proportional controller with ALMEMO® analog output modules | |
|||||
| Timer Controllers with ALMEMO® output relays | ||||||
| PID controller with ALMEMO® analog output modules and arithmetic channels | ||||||
Configuration Management and Printout
Configuration management |
||||||
| Save / load program configuration | ||||||
| Save / load calculation channels | ||||||
Printout of measuring data |
||||||
| Line diagram, Data table,Channellist | ||||||
| Bar diagrams, XY diagrams, project drawings, file overview incl. comments | ||||||
Password protection & Network server functions
Password protection |
||||||
| Protection against unauthorized access | ||||||
| Protection against operator error by assigning individual access rights | ||||||
| Traceability of activities by means of an events list | ||||||
| Alarm confirmation with user identification | ||||||
Network server functions |
||||||
| Displaying measured values and diagrams on Intranet or Internet | ||||||
| Embedding diagrams and project icons on your own Internet pages | ||||||
| Accessing the integrated web server via any browser | ||||||
| Accessing measured data and history data via TCP/IP (open text protocol) | ||||||
| Forwarding measured data to RMT WinControl | ||||||
| Availability of already acquired measured data even after program restart | ||||||
| Alarm confirmation via web server | ||||||
Options and Additional Modules
Options |
|||||||
| O1: | Network capability (for addressing several ALMEMO® devices) | |
|||||
| O2: | Automatic generation of measured data files (daily files / weekly files) | |
|||||
| O5: | Alarm function (alarm record, output to ALMEMO® relays, starting other applications) | |
|||||
| O8: | Data server | |
|||||
| O9: | Web server | |
|||||
| O10: | Extended evaluation functions | |
|||||
| O11: | Fast scanning of measured values for V7 devices (up to 1000 mops online) | ||||||
| O12: | PIMEX Player: combined measured value display and video display | ||||||
Additional modules: |
|||||||
| ZM1: | Thermal comfort and air-conditioning calculations (as per DIN 1946, EN ISO 7730) | ||||||
| ZM2: | Password protection | |
|||||
| ZM3: | Test bench manager | ||||||
| ZM4: | U-Value (Thermal transmittance) wizard | ||||||
| ZM5: | Thermal quantity wizard | ||||||
| ZM6: | OPC export | ||||||
| ZM7: | Additional protocol (selectve, e.g. OPC, Modbus, ...) | ||||||
| ZM8: | Security package including watchdog card | ||||||
| ZM9: | The memory is read out automatically | ||||||
| ZM10: | Automated printing (line diagrams, tables) | ||||||
| ZM11: | ODBC-Support (Export to SQLdatabases) | ||||||
| ZM12: | Assistant for calibrating measuring sensors | ||||||
| ZM13: | Assistant for calibrating climate cabinets | ||||||
| ZM14: | PIMEX Recorder: combined measured value recording and video recording | ||||||
1) only in combination with Option WCO2 (Auto Save)